You are viewing the site in preview mode

Skip to main content

Table 2 Comparison of monitored parameters during abdominal normothermic oxygenated recirculation (mean ± standard deviation)

From: Development of a preclinical model of donation after circulatory determination of death for translational application

  ANOR 1 ANOR 2 ANOR 3 ANOR 4 ANOR 5 ANOR 6
Weight (kg) 49 51 55 45 50 45
Pump flow rate (l/min) 2.5 ± 0.03 2.5 ± 0.03 2.8 ± 0.03 2.7 ± 0.05 2.6 ± 0.05 2.5 ± 0.03
Mean arterial pressure (mmHg) 65 ± 6 64 ± 5 84 ± 3 86 ± 10 77 ± 3 75 ± 6
Noradrenalin (μg/(kg min)) 0.7 ± 0.05 1.1 ± 0.19 0.6 ± 0.08 0.6 ± 0.2 0.6 ± 0.07 0.7 ± 0.15
Fraction of inspired oxygen (%) 56 ± 3 62 ± 5 59 ± 5 45 ± 2 54 ± 1 56 ± 3
Partial pressure of oxygen (mmHg) 123 ± 25 122 ± 16 141 ± 27 173 ± 31 149 ± 13 151 ± 19
Sweeping gas flow (l/min) 3.2 ± 0.2 4 ± 0 4.3 ± 0.2 3.3 ± 0.2 3.6 ± 0.1 3.5 ± 0
Partial pressure of carbon dioxide (mmHg) 37 ± 5 35 ± 1 35 ± 1 32 ± 2 30 ± 1 31 ± 1
Activated clotting time (s) 174 ± 32 183 ± 27 180 ± 21 198 ± 33 173 ± 20 171 ± 20
  1. ANOR, abdominal normothermic oxygenated recirculation.